1.7.7.89 /
(4.7/5) (56)
Loading...

Description

Operator panel for various industrial PLC's. Communication overBluetooth, WiFi or mobile internet with the protocols COMLI,Modbus/TCP (Class 0 and 1), Modbus RTU class 1, SattBus COMLI,Siemens Fetch/Write or Siemens S7 Communication (ISO on TCP). Canalso run on stationary devices such as media player or Raspberry Piand with cabled ethernet connection. HMI Droid is an evolution ofthe HMI program LEDpanel for Windows and is a supplement oralternative to traditional SCADA systems and operator panels. Ithandles logical and numerical variables and has easy navigationbetween panels (pages) using swipe gesture or with buttons. HMIDroid is also great to use for home automation with PLCs that haveeg Modbus/TCP protocol is implemented to remotely control andmonitor lighting, ventilation, heating etc in the residence orholiday home. Advantages: Excellent technical support. Freeupdates. Long expected life cycle. Graphic HMIs with touch functioncan be created in minutes. Free development tool with test runfeature. Virtually unlimited number of panels (pages), objects andvariables. Does not require any third-party services. Genuinenative app, not based on neither HTML nor OPC technology. Features:Parameters for communication such as IP address, port number,protocol, etc. can be specified per panel (page). Automatic pollingof all variables displayed in the current panel (page), no need forseparate tag list. Many formats for numeric variables such as 16and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.Prioritized event-driven transfer to the controller. Panels (pages)are edited in the measurement unit dp (Density Independent Pixels).Life bit for monitoring the operator panel in the controller.(Function similar to coordination area in Siemens S7.) Auto-scalingallows for using the same panels (pages) on smartphones, tabletsand other devices. Numeric variables can be displayed as predefinedtext for example alarms, sequence steps etc. Detailed diagnosticsof connection and communication. Variable areas for system andlocal variables. Possibility of automatic return to the start panel(page) after some time of inactivity. Selectable order for high andlow words of 32-bit variables in the Modbus protocol. Poll intervalcan be set do save data traffic or battery. Support for Greek,Turkish, Baltic, Central European, Eastern European, Cyrillic,Japanese (Shift JIS), Chinese (GB2312, BIG5) and Korean charactersets. Implemented protocols in the current version: COMLI: Message0, 1, 2, 3 and 4. Addresses register 0 - 3071 and flags 0 - 37777(octal). Modbus/TCP: Class 0, Function 3 and 16. Reads and writes64,512 holding registers. Modbus/TCP: Class 1, Function 1, 2, 4 and5. Reads 65,535 discrete inputs, 65,535 input registers and readsand writes 65,535 outputs (coils). Modbus RTU: Class 0 and 1.SattBus COMLI i.e. COMLI SattBus over Ethernet. SiemensFetch/Write: Reads and writes variables in data block 1 to 255between bytes 0 and 4095 and byte 0 to 127 in variable areas forinputs, outputs and memories. Siemens S7 Communication (ISO onTCP). System requirements: Android 3.2 or later. External storagemust be available. Windows PC for editing panels (pages). Downloadthe free development tool for PC that is used to make the panels(pages) to be run by HMI Droid:http://www.idea-teknik.com/en/hmi_droid_download.html Manual:http://www.idea-teknik.com/en/hmi_droid_manual.html Versionhistory:http://www.idea-teknik.com/en/hmi_droid_version_history.html

App Information HMI Droid

  • App Name
    HMI Droid
  • Package Name
    se.ideautomation.hmidroid
  • Updated
  • File Size
    402k
  • Requires Android
    Android 4.0 and up
  • Version
    1.7.7.89
  • Developer
    IDEA-Teknik
  • Installs
    1,000+
  • Price
    $7.00
  • Category
    Communication
  • Developer
    IDEA-Teknik / Jan Almqvist Långelanda-Stala 764 SE-472 93 SVANESUND
  • Google Play Link

IDEA-Teknik Show More...

HMI Droid 1.7.7.89 APK
IDEA-Teknik
Operator panel for various industrial PLC's. Communication overBluetooth, WiFi or mobile internet with the protocols COMLI,Modbus/TCP (Class 0 and 1), Modbus RTU class 1, SattBus COMLI,Siemens Fetch/Write or Siemens S7 Communication (ISO on TCP). Canalso run on stationary devices such as media player or Raspberry Piand with cabled ethernet connection. HMI Droid is an evolution ofthe HMI program LEDpanel for Windows and is a supplement oralternative to traditional SCADA systems and operator panels. Ithandles logical and numerical variables and has easy navigationbetween panels (pages) using swipe gesture or with buttons. HMIDroid is also great to use for home automation with PLCs that haveeg Modbus/TCP protocol is implemented to remotely control andmonitor lighting, ventilation, heating etc in the residence orholiday home. Advantages: Excellent technical support. Freeupdates. Long expected life cycle. Graphic HMIs with touch functioncan be created in minutes. Free development tool with test runfeature. Virtually unlimited number of panels (pages), objects andvariables. Does not require any third-party services. Genuinenative app, not based on neither HTML nor OPC technology. Features:Parameters for communication such as IP address, port number,protocol, etc. can be specified per panel (page). Automatic pollingof all variables displayed in the current panel (page), no need forseparate tag list. Many formats for numeric variables such as 16and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.Prioritized event-driven transfer to the controller. Panels (pages)are edited in the measurement unit dp (Density Independent Pixels).Life bit for monitoring the operator panel in the controller.(Function similar to coordination area in Siemens S7.) Auto-scalingallows for using the same panels (pages) on smartphones, tabletsand other devices. Numeric variables can be displayed as predefinedtext for example alarms, sequence steps etc. Detailed diagnosticsof connection and communication. Variable areas for system andlocal variables. Possibility of automatic return to the start panel(page) after some time of inactivity. Selectable order for high andlow words of 32-bit variables in the Modbus protocol. Poll intervalcan be set do save data traffic or battery. Support for Greek,Turkish, Baltic, Central European, Eastern European, Cyrillic,Japanese (Shift JIS), Chinese (GB2312, BIG5) and Korean charactersets. Implemented protocols in the current version: COMLI: Message0, 1, 2, 3 and 4. Addresses register 0 - 3071 and flags 0 - 37777(octal). Modbus/TCP: Class 0, Function 3 and 16. Reads and writes64,512 holding registers. Modbus/TCP: Class 1, Function 1, 2, 4 and5. Reads 65,535 discrete inputs, 65,535 input registers and readsand writes 65,535 outputs (coils). Modbus RTU: Class 0 and 1.SattBus COMLI i.e. COMLI SattBus over Ethernet. SiemensFetch/Write: Reads and writes variables in data block 1 to 255between bytes 0 and 4095 and byte 0 to 127 in variable areas forinputs, outputs and memories. Siemens S7 Communication (ISO onTCP). System requirements: Android 3.2 or later. External storagemust be available. Windows PC for editing panels (pages). Downloadthe free development tool for PC that is used to make the panels(pages) to be run by HMI Droid:http://www.idea-teknik.com/en/hmi_droid_download.html Manual:http://www.idea-teknik.com/en/hmi_droid_manual.html Versionhistory:http://www.idea-teknik.com/en/hmi_droid_version_history.html
Loading...