21 / August 17, 2017
(4.6/5) (95)

دەربارە

Save time, improve quality and safety in non-destructive testingthrough the CND radio application which make easier all calculationmethods. FEATURES: - Application for calculating the exposure timein gamma (Iridium 192 - Selenium 75) - Converter inch thickdiameter Dn Shedule - Half value layer - Half-Life - Marking fixedand mobile site - Mitigation of dose rate by material - ConversionTBq mGy / h - Conversion Bq Ci - EN1435 shooting technics -Geometric Blur

App Information NDT Radio

  • App Name
    NDT Radio
  • ناوی پاکەیج
    com.flamstudio.radio
  • Updated
    August 17, 2017
  • قەبارەی فایل
    2.7M
  • پێویستی بە ئەندرۆیدە
    Android 4.0.3 and up
  • وەشان
    21
  • گەشەپێدەر
    flamstudio
  • دابەزاندن
    5,000+
  • Price
    خۆراییە
  • هاوپۆڵ
    Tools
  • گەشەپێدەر
  • Google Play Link

flamstudio درێژە...

CND Radiographie industrielle 2 APK
flamstudio
Outils en contrôles non destructifs -Application pour calcul du temps de pose en gamma (Iridium 192 -Sélénium 75) - Convertisseur épaisseur pouce Dn Diamètre Shedule -CDA - Période radioactive - Balisage en chantier fixe et mobile -Atténuation du débit de dose par la matière - Conversion TBq enmGy/h - Conversion Bq en Ci - EN1435 Technique de tir - Influenced'un filtre en plomb sur le temps d'exposition.Page officiel facebook : https://www.facebook.com/cndradioNDT tools - Applicationfor calculating the exposure time in gamma (Iridium 192 - Selenium75) - Converter inch thick diameter Dn Shedule - CDA - Half-Life -Marking fixed and mobile site - Attenuation of dose rate bymaterial - Conversion TBq mGy / h - Conversion Bq Ci - EN1435Shooting Technique - Influence of a lead filter on the exposuretime.Official facebook page: https://www.facebook.com/cndradio
NDT Industrial Radiography 1.0 APK
flamstudio
Application for calculating the exposure timein gamma (Iridium 192 - Selenium 75) - Converter inch thickdiameter Dn Shedule - CDA - Half-Life - Marking fixed and mobilesite - Attenuation of dose rate by material - Conversion TBq mGy /h - Conversion Bq Ci - EN1435 shooting technique - Influence of alead filter on the exposure time.
NDT Radio 21 APK
flamstudio
Save time, improve quality and safety in non-destructive testingthrough the CND radio application which make easier all calculationmethods. FEATURES: - Application for calculating the exposure timein gamma (Iridium 192 - Selenium 75) - Converter inch thickdiameter Dn Shedule - Half value layer - Half-Life - Marking fixedand mobile site - Mitigation of dose rate by material - ConversionTBq mGy / h - Conversion Bq Ci - EN1435 shooting technics -Geometric Blur